<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Endoscope Washers | Moonmed</title>
	<atom:link href="https://www.moonmed.com/medical/medical-washer-disinfector/endoscope-washers/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.moonmed.com/medical/medical-washer-disinfector/endoscope-washers/</link>
	<description></description>
	<lastBuildDate>Sun, 09 Oct 2016 09:55:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://www.moonmed.com/wp-content/uploads/2016/06/cropped-moonmed_2-compressed-1-32x32.jpg</url>
	<title>Endoscope Washers | Moonmed</title>
	<link>https://www.moonmed.com/medical/medical-washer-disinfector/endoscope-washers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Endoscope Washer Disinfector Dryers and Storage  : Moonmed</title>
		<link>https://www.moonmed.com/endoscope-washer-disinfector-dryers-storage-moonmed/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=endoscope-washer-disinfector-dryers-storage-moonmed</link>
					<comments>https://www.moonmed.com/endoscope-washer-disinfector-dryers-storage-moonmed/#respond</comments>
		
		<dc:creator><![CDATA[admin1]]></dc:creator>
		<pubDate>Sun, 09 Oct 2016 09:53:58 +0000</pubDate>
				<category><![CDATA[Endoscope Washers]]></category>
		<category><![CDATA[Medical Washer Disinfector]]></category>
		<guid isPermaLink="false">http://moonmed.com/?p=4621</guid>

					<description><![CDATA[<p>&#160; A medical instrument or device could be single use or reusable. Single use medical instruments or devices like syringes are not reused while reusable medical instruments or devices like endoscopes must undergo a cleaning and sterilization/disinfection process. This is essential to prevent outbreak of infections and promote patient&#8217;s safety. Endoscopy involves examining or looking [&#8230;]</p>
<p>The post <a href="https://www.moonmed.com/endoscope-washer-disinfector-dryers-storage-moonmed/">Endoscope Washer Disinfector Dryers and Storage  : Moonmed</a> appeared first on <a href="https://www.moonmed.com">Moonmed</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="aligncenter wp-image-4622" src="http://moonmed.com/wp-content/uploads/2016/10/Endoscope-Washer.jpg" alt="Endoscope Washer &amp; Disinfector Dryers" width="501" height="414" srcset="https://www.moonmed.com/wp-content/uploads/2016/10/Endoscope-Washer.jpg 480w, https://www.moonmed.com/wp-content/uploads/2016/10/Endoscope-Washer-150x124.jpg 150w, https://www.moonmed.com/wp-content/uploads/2016/10/Endoscope-Washer-300x248.jpg 300w" sizes="(max-width: 501px) 100vw, 501px" /></p>
<p>&nbsp;</p>
<p>A medical instrument or device could be single use or reusable. Single use medical instruments or devices like syringes are not reused while reusable medical instruments or devices like endoscopes must undergo a cleaning and sterilization/disinfection process. This is essential to prevent outbreak of infections and promote patient&#8217;s safety.</p>
<p>Endoscopy involves examining or looking inside a person&#8217;s body, usually the digestive system, for medical reasons. This is done with the aid of an endoscope. An endoscope is a long, thin, flexible/rigid medical imaging tube with a light and camera attached for capturing images of the body part being examined. It is inserted through a natural opening such as the mouth cavity or the rectum.</p>
<p>An endoscope is a reusable medical instrument and the only medical imaging device that is inserted directly into the organ being examined. This makes it a critical medical instrument for sterilization according to Spaulding&#8217;s classification as quoted in Disinfection and Sterilization Infection Control Guidelines, 2009. After using an endoscope, it must pass through different cleaning and disinfection processes before it can be used again.</p>
<p>Another issue of note is it&#8217;s drying and storage after cleaning and sterilizing. Several manufacturers offer several models. Models currently available include: Steelco, Medivators, Soluscope, Escad, Afos, Wassernburg, Logiquip, and Scope-store. This list is not exhaustive.</p>
<p>It will be unfair to pick one model as better than all others. So in making a choice, it&#8217;s advised you consider features that relate to your organization&#8217;s specific needs, while ensuring it meets the Association of Advancement of Medical Instruments (AAMI) standards which are it&#8217;s  shelf’s must be vertical to aid drainage and metal to prevent moisture retention.</p>
<p>Drying Mechanism</p>
<p>Endoscopes are dried at low temperature with medical-grade air. Majority of models meet this requirement by continuously flushing the chamber with steriled HEPA-filtered air.</p>
<p>Storage Capacity and Compatibility</p>
<p>Capacity is number of endoscopes that can be stored, it ranges from as low as five to as high as sixteen. Steelco has the highest capacity of sixteen, Medivator and Arc have a capacity of ten, Soluscope has eight, while Olympus has the lowest of seven.</p>
<p>Compatibility varies meaning while some models can store endoscopes from other brands, other models cannot store endoscopes from other brands. Although, Olympus has the lowest capacity, it appears to be the only brand that is compatible with other brands.</p>
<p>DURATION OF STORAGE</p>
<p>The endoscope passes through the process of cleaning and sterilizing when used before it is stored for future use. Duration of storage is how long can it be stored without re-sterilizing before use. Most models are 72 hours, Soluscope is 7 days, Wassernburg is 30 days while Medivator has the longest at 31 days.</p>
<p>Traceability</p>
<p>Radio Frequency ID(RFID) helps to keep track of endoscope use and ensure unauthorized persons have no access. A latest models are fitted with this technology.</p>
<p>Documentation</p>
<p>Documenting the conditions of endoscopes helps to determine if they are in working conditions when needed. This feature is available at Olympus and Escad.</p>
<p>Other side features include smart light to indicate progress and condition of endoscope which escad has. Capacity to integrate with IT services like HIS, current models have this capacity.</p>
<p>Guarantee your patient&#8217;s biological safety with an effective endoscope dryer and storage.</p>
<p>The post <a href="https://www.moonmed.com/endoscope-washer-disinfector-dryers-storage-moonmed/">Endoscope Washer Disinfector Dryers and Storage  : Moonmed</a> appeared first on <a href="https://www.moonmed.com">Moonmed</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.moonmed.com/endoscope-washer-disinfector-dryers-storage-moonmed/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4621</post-id>	</item>
		<item>
		<title>Endoscope Washers &#8211; Moon Rider 50 and 60 series</title>
		<link>https://www.moonmed.com/endoscope-washers-moon-rider-50-and-60-series/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=endoscope-washers-moon-rider-50-and-60-series</link>
					<comments>https://www.moonmed.com/endoscope-washers-moon-rider-50-and-60-series/#respond</comments>
		
		<dc:creator><![CDATA[admin1]]></dc:creator>
		<pubDate>Mon, 16 Mar 2015 15:20:51 +0000</pubDate>
				<category><![CDATA[Endoscope Washers]]></category>
		<guid isPermaLink="false">http://moonmed.com/?p=3665</guid>

					<description><![CDATA[<p>MODEL: MO-MOON-RIDER-50/60 series</p>
<p>The post <a href="https://www.moonmed.com/endoscope-washers-moon-rider-50-and-60-series/">Endoscope Washers &#8211; Moon Rider 50 and 60 series</a> appeared first on <a href="https://www.moonmed.com">Moonmed</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-full wp-image-4600" src="http://moonmed.com/wp-content/uploads/2015/03/Rider-1.jpg" alt="rider-1" width="480" height="397" srcset="https://www.moonmed.com/wp-content/uploads/2015/03/Rider-1.jpg 480w, https://www.moonmed.com/wp-content/uploads/2015/03/Rider-1-150x124.jpg 150w, https://www.moonmed.com/wp-content/uploads/2015/03/Rider-1-300x248.jpg 300w" sizes="(max-width: 480px) 100vw, 480px" /></p>
<h3>MODEL: MO-MOON-RIDER-50/60 series</h3>
<div class="shortcode_tabs tab-style-one" data-rt-animate="animate" data-rt-animation-type="fadeIn" data-rt-animation-group="single"><div class="tabs_wrap"><ul class="tabs clearfix"><li><a href="#">Product Details</a></li><li><a href="#">Technical Data</a></li><li><a href="#">Accessories</a></li><li><a href="#">Documentation</a></li><li><a href="#">Click to request a quote</a></li></ul><div class="panes">
 <div class="pane fluid">
<p><img decoding="async" class="alignnone size-full wp-image-4606" src="http://moonmed.com/wp-content/uploads/2015/03/endoscope-page-1.jpg" alt="endoscope-page-1" width="713" height="906" srcset="https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-1.jpg 713w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-1-118x150.jpg 118w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-1-236x300.jpg 236w" sizes="(max-width: 713px) 100vw, 713px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-4607" src="http://moonmed.com/wp-content/uploads/2015/03/endoscope-page-2.jpg" alt="endoscope-page-2" width="714" height="846" srcset="https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-2.jpg 714w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-2-127x150.jpg 127w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-page-2-253x300.jpg 253w" sizes="auto, (max-width: 714px) 100vw, 714px" /></p>
<p>&nbsp;</p>
<h2>MO-Moon-Rider Endoscope Washer Disinfector</h2>
<h6>The Moon Rider endoscope washers disinfector is fully automatic and is developed according to the ISO 15883-4 standard.</h6>
<p>It works with various kinds of disinfectants such as: Glutaraldehyde, peracetic acid, phthalic dicarboxaldehyde, chlorine dioxide, acidic electrolyzed oxidizing water.</p>
<h4>Endoscope protection design</h4>
<p><strong>&#8211; Leaking test function</strong></p>
<p>The leaking test will finish before the endoscope comes into contact with the liquid and will also keep on testing during the operation. The system gives out visual and audible signals and will terminate the operation as soon as the leaking value exceeds the set value.</p>
<p><strong>&#8211; Blocking test function</strong></p>
<p>The blocking test will start before the endoscope comes into contact with the liquid. The system gives out visual and audible signals and will terminate the operation as soon as the pipe is found to be blocked.</p>
<p><strong>&#8211; Self-disinfection function</strong></p>
<p>The self-disinfection program can be started during maintenance or after the termination of the operation cycle. This function is designed to disinfect the wash-disinfection tank (includes 0.2μm filter) and the internal pipelines.</p>
<p><strong>&#8211; Leak Test Cycle (process)</strong></p>
<p>Washing, Enzyme Washing, Rinse, Disinfection 5 minutes, sterile water rinse and drying</p>
<p><strong>&#8211; Fast wash and disinfection</strong></p>
<p>An endoscope can be wash-disinfected within 15minutes by the Moon Rider which dramatically improves the endoscope turnover efficiency.</p>
<h4>Moon Rider 60 Series</h4>
<p><strong>&#8211; Process traceability system</strong></p>
<p><strong>&#8211; Process data printing</strong></p>
<p>For filing purposes the printer will print out all of the processed data in timely intervals during the operation.</p>
<p><strong>&#8211; Process data management</strong></p>
<p>The system collects the information of endoscope and the operator and then connects the process data with the computer management system to achieve synchronization and management of patient and the disinfection information.</p>
<p>Operator information is recorded</p>
<p>Endoscope information is recorded</p>
<p>100% wash-disinfection</p>
<p><strong>&#8211; Wash-disinfection</strong></p>
<p>The tank is equipped with a rotating nozzle and spray arm to wash the outer surface of the endoscope and in the meanwhile the circulating water flow keeps flushing the endoscope from the inside.</p>
<p><strong>&#8211; Endoscope pressure booster pump</strong></p>
<p>This is used for washing of the intricate small pipes for the air/water injection nozzles, to reduce the formation probability of bacteria and biofilm.</p>
<p><strong>&#8211; Sterile water rinse</strong></p>
<p>To avoid secondary contamination caused by unsanitary water, the endoscope will be rinsed by sterile filtered water through 0.2μm filter after disinfection.</p>
<p><strong>&#8211; Drying function</strong></p>
<p>It is used for drying the inner and outer surface of endoscope. Moon Rider equipped with air drying and alcohol drying for the user to select.</p>
<h4><strong>Perfect medical workers protection</strong></h4>
<p><strong>&#8211; Automatic door with foot switch</strong></p>
<p>The automatic visual glass door is adopted for observing the operation inside the tank during the cycle. The door can be opened by gently kicking the foot switch.</p>
<p><strong>&#8211; Totally-enclosed</strong></p>
<p>Moon Rider wash-disinfection tank is a totally-enclosed structure to avoid chemical odor leakage and to protect the operators and medical workers.</p>
<p><strong>&#8211; Automatic Chemical injection</strong></p>
<p>Medical staff operators only need to link the chemical container with the tank through a connector to avoid any harm that could be caused from manual chemical pouring.</p>
<h4>MO-MOON-RIDER-50/60 series</h4>
</div>
 <div class="pane fluid">
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-4608" src="http://moonmed.com/wp-content/uploads/2015/03/endoscope-Technical-page-3.jpg" alt="endoscope-technical-page-3" width="717" height="940" srcset="https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-Technical-page-3.jpg 717w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-Technical-page-3-114x150.jpg 114w, https://www.moonmed.com/wp-content/uploads/2015/03/endoscope-Technical-page-3-229x300.jpg 229w" sizes="auto, (max-width: 717px) 100vw, 717px" /></p>
<h4>MO-MOON-RIDER-50/60/</h4>
<h4></div>
 <div class="pane fluid">
See Brochure and request a quote<br />
</div>
 <div class="pane fluid">
<img decoding="async" style="float: left;" src="http://moonmed.com/wp-content/uploads/2015/03/pdficon_large.png" alt="Download Product Datasheet" /><a href="http://moonmed.com/wp-content/uploads/2015/03/Endoscope-Washer_MO-MOON-RIDER-50-60_FI210716.pdf" rel="">endoscope-washer_mo-moon-rider-50-60_fi210716</a><br />
</div></h4>
 <div class="pane fluid">
[contact-form-7]<br />
</div>
</div></div></div>
<p>The post <a href="https://www.moonmed.com/endoscope-washers-moon-rider-50-and-60-series/">Endoscope Washers &#8211; Moon Rider 50 and 60 series</a> appeared first on <a href="https://www.moonmed.com">Moonmed</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.moonmed.com/endoscope-washers-moon-rider-50-and-60-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3665</post-id>	</item>
	</channel>
</rss>
